CA25T Pneumatische elektromagnetische pulsafsluiter
Use period
|
Failure phenomena
|
Possible Reason
|
Troubleshooting
|
During installation and commissioning
|
The valves cannot all be opened, but the leading part does act.
|
Check the gas dome pressure to see if it is too low.
|
Check the leakage
|
Some valves do not work, but the others are normal.
|
Check the valve coil connection and coil
|
Replace the accessories
|
|
The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.
|
Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.
|
Check the leakage
|
|
Z-valve. The valve inlet and blowing muzzle are installed backwards.
|
Re-install
|
||
Some valves cannot be closed. There is leakage.
|
There is some dirt or debris on the membrane, ii is blocking the moving iron core.
|
Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
|
|
A valve closing is slowly.
|
The membrane orifice is blocked.
|
Dredge the membrane orifice
|
|
During use period
|
Some valves are leaking. The membrane cannot close tightly and the valve is always open a
little.
|
There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.
|
Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
|
Coil is hot and burned out.
|
It has been turned on for too long.
|
Check the working condition of the control system.
|
|
Voltage exists but the valve does not operate.
|
Membrane is damaged and the orifice is blocked.
|
Replace the accessories in time.
|
|
Ambient temperature is below -20℃. The valve is leaking and cannot open.
|
Ambient temperature is too low and here is frost in the valve.
|
Pay attention to insulation and maintaining proper temperatures.
|
Voordat u onderhoudswerkzaamheden aan het systeem uitvoert, moet u ervoor zorgen dat componenten volledig geïsoleerd zijn van druk en stroom
levert. Druk en stroom mogen niet opnieuw worden toegepast totdat de klep volledig is gemonteerd. membraan- en pilootinspectie
moet jaarlijks worden uitgevoerd.
De VOORDELEN die onze producten hebben:
Het klephuis en het deksel zijn gegoten, compact en bedekt met heldere verf om de corrosiebestendigheid te verbeteren.
Het afdichtingskussen op het membraan is gemaakt van metaal en rubber, dat stijf is en niet lekt.
Elektromagnetische leidkopzuiging, gevoelige en betrouwbare actie.
Elkaar: hetzelfde model, specificaties van alle andere producten, onderdelen kunnen universeel, uitwisselbaar zijn.
Stabiele en betrouwbare prestaties, de levensduur van het membraan bereikt meer dan 1 miljoen keer.
Geef ons alstublieft de aanvraag!
Product Categorie : Stofafscheider pulsklep > Pulsstraalklep
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.